Description
Implement standard: AHA (American Heart Association) 2020 guideline for CPR and ECC
Advanced CPR Training Manikin Voice Guided with Monitor & Printer Features:
- Clear anatomic characteristic, realistic touch feeling and lifelike skin color, vivid appearance;
- Simulate vital signs:
(1) Initial state: manikin pupils are dilated, no carotid artery pulse;
(2) During the compression operation, there is passive pulse of carotid artery, and the pulse rate is in line with compression rate;
(3) After successful rescue, the manikin pupils return to normal and get spontaneous carotid artery pulse;
- Provide consciousness judgment, emergency call, pulse examination, breath examination and foreign body clearance operation;
- Can perform artificial breathing and cardiac compression, airway open;
- Three operation modes: CPR training, simulating assessment and actual assessment
(1) Mode I: CPR training, can perform compression and inflation
(2) Mode II: Simulating assessment, during the rated period complete 5 cycles CPR operation basing on 2020 international CPR standard, with compression and inflation ratio: 30:2;
(3) Mode III: Actual assessment, during the setting period, complete the pre-set assessment rules according to the 2020 international CPR standard.
CPR Screen Features:
- Electronic monitoring: Monitor airway open and compression site; show the correct No. and wrong No. of artificial breath and external cardiac compression;
- Voice prompt: English voice prompt during the training and assessment operation; voice can be closed or open, volume can be adjusted;
- Indicators show inflation volume, correct inflation volume: 500/600ml—1000ml;
(1) Insufficient inflation volume, yellow indicator
(2) Proper inflation volume, green indicator
(3) Excessive inflation volume, red indicator
- Indicators show compression depth: correct compression depth: 5-6cm
(1) Insufficient compression depth, yellow indicator;
(2) Proper compression depth, green indicator
(3) Excessive compression depth, red indicator;
- Operation time can be set in second;
- Operation rate: ≥100 times/min
- Power: 220V, 24V output powder via manostat
Printer:
- Available synchronous printing while operation
- Print after the operation is finished
- The content of result sheet covers operation mode, consciousness judgment, emergency call, pulse examination, breath examination, foreign body clearance, inflation and compression number every operation cycle, correct/wrong compression , reason for wrong compression ,correct/wrong inflation, reason for incorrect inflation, time setting, operation time, assessment evaluation.
RF Remote Controller:
RF remote controller: teacher can control CPR operation, pupil changes, pulse activity, print and other functions by using remote controller; can also record conscious judgment, emergency call, pulse examination, breath examination, and foreign body clearance.
eliteplus –